Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
1.
Braz. dent. sci ; 26(3): 1-13, 2023. ilus, tab
Article in English | LILACS, BBO | ID: biblio-1444656

ABSTRACT

Objective: this double-blind randomized clinical trial evaluate the clinical performance of Thermo-Viscous Bulk Fill composite, Self-Adhesive Flowable composite, and Filtek Bulk Fill Composites restorations in Class I cavities over a period of 18 months. Material and Methods: twenty individuals between the ages of 30 and 45 participated in this research. Each patient should have at least three occlusal Class I carious lesions on their molars. They were dispersed at random, with n=20 teeth representing each tested material. Group I (Futurabond M+ and VisCalor Bulk Fill which heated in a viscolar dispenser at 68 °C for 30s and placed in a 4 mm thickness), Group II (Fusio Liquid Dentin self-adhesive composite which put in a thin layer (1mm increment)), and Group III (Single Bond Universal and Filtek Bulk Fill Posterior composite which applied in 4 mm thickness without heating). Using (USPHS) criteria, all restorations were assessed clinically at baseline, 6 months, 12 months, and 18 months. Using an inverse replica, the marginal seal of the investigated restorations was further evaluated under SEM. Statistical analysis was performed with Chi-square test for all USPH parameters. Results: the three tested groups recorded a one hundred percent retention rate after 18 months follow up period. Concerning marginal adaptation, marginal discoloration, anatomical form, surface texture, and color matching, there was a significant difference (p˂0.05) between the three tested groups after 12 & 18 months. After 12 & 18 months, SEM analysis of the marginal seal revealed a statistically significant difference between the three groups. Conclusion: Bulk fill resin composite restorations showed satisfactory acceptable clinical performance after 18 months of clinical service compared to self-adhesive flowable composites, and Viscalor Bulk Fill composite demonstrated excellent results with considerable changes in marginal integrity as a consequence of thermal viscous technology and increased adaptability of restorations toward cavity walls and margins (AU)


Objetivo: este ensaio clínico randomizado duplo-cego avaliou o desempenho clínico de restaurações de resina Bulk Fill Termo-Viscosa, resina autoadesiva Flowable e Filtek Bulk Fill Composites em cavidades Classe I durante um período de 18 meses. Material e Métodos: 20 indivíduos com idade entre 30 e 45 anos participaram da pesquisa. Cada paciente deveria ter pelo menos três lesões de cárie oclusais de Classe I nos molares. Eles foram divididos aleatoriamente, com n=20 dentes representando cada material testado. Grupo I (Futurabond M+ e VisCalor Bulk Fill aquecido em dispensador viscolar a 68 °C por 30s e colocado em uma espessura de 4 mm), Grupo II (resina composta autoadesiva Fusio Liquid Dentin colocada em uma camada fina (incremento de 1 mm)) e Grupo III (resina composta Single Bond Universal e Filtek Bulk Fill Posterior aplicado em espessura de 4 mm sem aquecimento). Usando os critérios (USPHS), todas as restaurações foram avaliadas clinicamente no início, 6 meses, 12 meses e 18 meses. Usando uma réplica inversa, o selamento marginal das restaurações investigadas foi avaliado em MEV. A análise estatística foi realizada com o teste qui-quadrado para todos os parâmetros USPH. Resultados: os três grupos testados registraram uma taxa de retenção de cem por cento após um período de acompanhamento de 18 meses. Em relação à adaptação marginal, descoloração marginal, forma anatômica, textura da superfície e combinação de cores, houve uma diferença significativa (p˂0,05) entre os três grupos testados após 12 e 18 meses. Após 12 e 18 meses, a análise SEM do selamento marginal revelou uma diferença estatisticamente significativa entre os três grupos. Conclusão: as restaurações de resina composta Bulk Fill apresentaram desempenho clínico aceitável satisfatório após 18 meses de atendimento clínico em comparação com as resinas compostas fluidas autoadesivas, e a resina composta Viscalor Bulk Fill demonstrou excelentes resultados com mudanças consideráveis na integridade marginal, como consequência da tecnologia viscosa térmica e maior adaptabilidade de restaurações nas paredes e margens da cavidade (AU)


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Microscopy, Electron, Scanning , Malocclusion, Angle Class I
2.
Braz. j. otorhinolaryngol. (Impr.) ; 86(1): 30-37, Jan.-Feb. 2020. tab, graf
Article in English | LILACS | ID: biblio-1089360

ABSTRACT

Abstract Introduction Ototoxicity is a health problem appearing after powerful treatments in serious health conditions. It is sometimes inevitable when treatment of the serious disease is required. Cisplatin is an antineoplastic agent which was investigated previously to reveal increased nitrogen and reactive oxygen radicals that damages hair cells, resulting in ototoxicity. N-acetylcysteine, previously shown to decrease ototoxicity caused by different agents, is known to be a powerful in vitro antioxidant. Probably N-acetylcysteine, in addition to its antioxidant effect, blocks a cascade where reactive oxygen species result in apoptosis in the cochlea. Objectives The possible preventive effect of N-acetylcysteine in cisplatin ototoxicity was studied with auditory brain stem responses, otoacoustic emissions, and histopathological investigation of the cochlea in a scanning electron microscopy. Methods This study was conducted on 21 Wistar Albino rats in four groups. 1 mL/kg/day three times in total intraperitoneal (i.p.) Saline (n = 5), 500 mg/kg/day i.p. three times in total N-acetylcysteine (n = 5), i.p. 15 mg/kg cisplatin alone (single dose) (n = 5) and i.p. 15 mg/kg cisplatin plus 500 mg/kg/day N-acetylcysteine (n = 6) were administered. The rats were anesthetized to study the hearing tests before and after the experiment. The rats were sacrificed to investigate the cochleas by scanning electron microscopy. Results Auditory brain stem responses and otoacoustic emissions values were attenuated in the cisplatin group. The group that received N-acetylcysteine in addition to cisplatin had better auditory brain stem responses thresholds and otoacoustic emissions. The samples obtained from the cisplatin group showed surface irregularities, degeneration areas, and total or partial severe stereocilia losses. The changes were milder in the cisplatin + N-acetylcysteine group. Conclusion Cisplatin ototoxicity can be detected by auditory brain stem responses and otoacoustic emissions testing in rats. N-acetylcysteine may protect the cochlear cells from histopathological changes. We concluded that N-acetylcysteine given 4 h after cisplatin injection has a potential otoprotective effect against cisplatin ototoxicity. which suggests it could be used in clinical trials.


Resumo Introdução A ototoxicidade é um problema que pode ocorrer após certos tipos de tratamentos para condições graves de saúde. Às vezes é inevitável quando o tratamento da doença é necessário. A cisplatina é um agente antineoplásico cujo uso em pesquisas anteriores demonstrou aumentar os radicais livres de nitrogênio e espécies reativas de oxigênio que danificam as células ciliadas e resultam em ototoxicidade. Por outro lado, a N-acetilcisteína, que já demonstrou diminuir a ototoxicidade causada por diferentes agentes, é conhecida por ser um potente antioxidante in vitro. Provavelmente a N-acetilcisteína, além de seu efeito antioxidante, bloqueia uma cascata onde espécies reativas de oxigênio resultam em apoptose na cóclea. Objetivos Estudar o possível efeito preventivo da N-acetilcisteína na ototoxicidade por cisplatina por meio de potencial evocado auditivo de tronco encefálico, emissões otoacústicas e investigação histopatológica da cóclea por microscopia eletrônica de varredura. Método Este estudo foi realizado em 21 ratos albinos Wistar, separados em quatro grupos. Foram administrados: 1 mL/kg/dia intraperitoneal (i.p.) de solução salina (n = 5), três vezes no total; 500 mg/kg/dia i.p. de N-acetilcisteína (n = 5), três vezes no total; 15 mg/kg i.p. (dose única) somente de cisplatina (n = 5) e 15 mg/kg i.p. de cisplatina e 500 mg/kg/dia i.p. de N-acetilcisteína (n = 6). Os ratos foram anestesiados para estudo dos testes auditivos antes e depois do experimento. Os ratos foram sacrificados para investigação da cóclea por microscopia eletrônica de varredura. Resultados Os potenciais evocados auditivos de tronco encefálico e os valores das emissões otoacústicas estavam atenuados no grupo cisplatina. O grupo que recebeu N-acetilcisteína além da cisplatina apresentou melhores limiares de respostas auditivas do tronco encefálico e emissões otoacústicas. As amostras obtidas do grupo cisplatina apresentaram irregularidades de superfície, áreas de degeneração, com perdas graves totais ou parciais de estereocílios. As alterações foram mais leves no grupo cisplatina + N-acetilcisteína. Conclusão A ototoxicidade por cisplatina pode ser detectada por meio de potenciais evocados auditivos de tronco encefálico e pelo teste de emissões otoacústicas em ratos. A N-acetilcisteína pode proteger as células cocleares contra alterações histopatológicas. Concluímos que a N-acetilcisteína administrada 4 horas após a injeção de cisplatina tem potencial efeito otoprotetor contra a ototoxicidade por cisplatina e pode ser utilizada em ensaios clínicos.


Subject(s)
Animals , Male , Acetylcysteine/administration & dosage , Cisplatin/adverse effects , Protective Agents/administration & dosage , Ototoxicity/etiology , Antineoplastic Agents/adverse effects , Antioxidants/administration & dosage , Acetylcysteine/pharmacology , Microscopy, Electron, Scanning , Evoked Potentials, Auditory, Brain Stem , Rats, Wistar , Cochlea/pathology , Apoptosis , Hair Cells, Auditory, Outer/drug effects , Hair Cells, Auditory, Outer/pathology , Protective Agents/pharmacology , Disease Models, Animal , Stereocilia/drug effects , Stereocilia/pathology , Ototoxicity/prevention & control , Hearing Tests , Antioxidants/pharmacology
3.
Braz. dent. sci ; 22(3): 305-312, 2019. tab, ilus
Article in English | LILACS, BBO | ID: biblio-1008364

ABSTRACT

Objective: The aim of the study was to evaluate the influence of different surface post-etching treatments in flexural strength, contact angle and surface roughness of a lithium disilicate ceramic. Material and Methods: 60 bars (16 x 2 x 4 mm) were divided in six groups (n=10): C, no treatment; HF, hydrofluoric acid for 20 s (HF) + washing (60 s), drying (30s); HFL, HF + washing (60 s), drying (30 s) and luting; HFNL, HF + washing (60 s) + neutralization with sodium bicarbonate (SB) for 40 s + washing (5s), drying (30 s) and luting; HFUL, HF + washing (60 s) + ultrasonic bath (UB) for 4 min, drying (30 s) and luting; HFNUL, HF + washing (60 s) + SB (40 s) + UB (4 min) and luting. The bars were submitted to three-points flexural strength test. 25 ceramic blocks (12 x 7 x 7 mm) were divided into five groups (n=5) to evaluate roughness and contact angle C - no treatment; HF - HF ; HFU - HF and UB for 5 min ; HFN - HF and SB; HFNU - HF, UB and SB. A scanning electron microscope (SEM) showed the surface of the samples. ANOVA one-way statistical analysis was done for comparison of results. Results: There was no statistical difference for flexural strength (p-value = 0.15) and for surface roughness (p-valor = 0.15). However, it was obtained statistically significant difference for contact angle (p-valor = 0.00). SEM images showed precipitates after the acid etching, which were removed by post-etching treatments. Conclusion: It can be concluded that the different post-etching surface treatments did not increase the flexural strength, surface roughness, but it influenced the ceramic wetting and SEM images (AU)


Objetivo: O objetivo do estudo foi avaliar a influência de diferentes tratamentos pós-condicionamento na resistência à flexão, ângulo de contato e rugosidade superficial de uma cerâmica de dissilicato de lítio. Material e Métodos: 60 barras (16 x 2 x 4 mm) foram divididas em seis grupos (n = 10): C, sem tratamento; HF, ácido fluorídrico durante 20 s (HF) + lavagem (60 s), secagem (30 s); HFL, lavagem com HF + (60 s), secagem (30 s) e cimentação; HFNL, HF + lavagem (60 s) + neutralização com bicarbonato de sódio (SB) por 40 s + lavagem (5s), secagem (30 s) e cimentação; HFUL, HF + lavagem (60 s) + banho ultrassônico (UB) por 4 min, secagem (30 s) e cimentação; HFNUL, HF + lavagem (60 s) + SB (40 s) + UB (4 min) e cimentação. As barras foram submetidas ao teste de resistência à flexão de três pontos. 25 blocos cerâmicos (12 x 7 x 7 mm) foram divididos em cinco grupos (n = 5) para avaliação da rugosidade superficial e ângulo de contato C - sem tratamento; HF - HF; HFU - HF e UB por 5 min; HFN - HF e SB; HFNU - HF, UB e SB. Um microscópio eletrônico de varredura (MEV) foi utilizado para análise da superfície das amostras. A análise estatística unidirecional ANOVA-um fator foi realizada para comparação dos resultados. Resultados: Não houve diferença estatística para a resistência à flexão (p-valor = 0,15) e para a rugosidade superficial (p-valor = 0,15). No entanto, obteve-se diferença estatisticamente significante para o ângulo de contato (p-valor = 0,00). Imagens de microscopia eletrônica de varredura mostraram a formação de precipitados após o ataque ácido, que foram removidos pelos tratamentos pós-condicionamento. Conclusão: Pode-se concluir que os diferentes tratamentos de superfície pós-condicionamento não aumentaram a resistência à flexão, rugosidade da superfície, mas influenciaram na molhabilidade da cerâmica e nas imagens em MEV.(AU)


Subject(s)
Electron Microscope Tomography , Flexural Strength , Hydrofluoric Acid
4.
Rev. bras. anestesiol ; 65(6): 491-496, Nov.-Dec. 2015. tab, graf
Article in Portuguese | LILACS | ID: lil-769891

ABSTRACT

BACKGROUND AND OBJECTIVES: Epidural catheter bacteria filters are barriers in the patient-controlled analgesia/anaesthesia for preventing contamination at the epidural insertion site. The efficiency of these filters varies according to pore sizes and materials. METHOD: The bacterial adhesion capability of the two filters was measured in vitro experiment. Adhesion capacities for standard Staphylococcus aureus (ATCC 25923) and Pseudomonas aeruginosa (ATCC 27853) strains of the two different filters (Portex and Rusch) which have the same pore size were examined. Bacterial suspension of 0.5 Mc Farland was placed in the patient-controlled analgesia pump, was filtered at a speed of 5 mL/h. in continuous infusion for 48 h and accumulated in bottle. The two filters were compared with colony counts of bacteria in the filters and bottles. At the same time, the filters and adhered bacteria were monitored by scanning electron microscope. RESULTS: Electron microscopic examination of filters showed that the Portex filter had a granular and the Rusch filter fibrillary structure. Colony counting from the catheter and bottle showed that both of the filters have significant bacterial adhesion capability (p < 0.001). After the bacteria suspension infusion, colony countings showed that the Portex filter was more efficient (p < 0.001). There was not any difference between S. aureus and P. aeruginosa bacteria adhesion. In the SEM monitoring after the infusion, it was physically shown that the bacteria were adhered efficiently by both of the filters. CONCLUSION: The granular structured filter was found statistically and significantly more successful than the fibrial. Although the pore sizes of the filters were same - of which structural differences shown by SEM were the same - it would not be right to attribute the changes in the efficiencies to only structural differences. Using microbiological and physical proofs with regard to efficiency at the same time has been another important aspect of this experiment.


JUSTIFICATIVA E OBJETIVOS: Os filtros antibacterianos para cateter epidural são barreiras da analgesia/anestesia controlada pelo paciente para evitar a contaminação do local de inserção epidural. A eficácia desses filtros varia de acordo com o material e o tamanho dos poros. MÉTODO: A capacidade de aderência bacteriana dos dois filtros foi medida em experimento in vitro. Avaliamos a capacidade de aderência das cepas padrão de Staphylococcus aureus (ATCC 25923) e Pseudomonas aeruginosa (ATCC 27853) de dois filtros diferentes (Portex e Rusch), mas com poros do mesmo tamanho. Uma suspensão bacteriana grau 0,5 de McFarland foi colocada na bomba de analgesia controlada pelo paciente e filtrada a uma velocidade de 5 mL/h em infusão contínua por 48 horas e acumulada em frasco. Os dois filtros foram comparados com contagens de colônias de bactérias nos filtros e frascos. Ao mesmo tempo, os filtros e as bactérias aderidas foram monitorados com microscópio eletrônico de varredura. RESULTADOS: O exame dos filtros por microscópico eletrônico mostrou que a estrutura do filtro Portex era granulada e a do filtro Rusch fibrilar. A contagem de colônias do cateter e do frasco mostrou que ambos os filtros tinham uma capacidade de adesão bacteriana significativa (p < 0,001). Após a infusão da suspensão bacteriana, as contagens de colônias mostraram que o filtro Portex foi mais eficiente (p < 0,001). Não houve qualquer diferença entre as adesões de bactérias S. aureus e P. aeruginosa. Na monitoração por MEV após a infusão, ficou fisicamente evidente que as bactérias foram aderidas de modo eficaz por ambos os filtros. CONCLUSÃO: O filtro com estrutura granular foi estatística e significativamente mais bem- sucedido do que o filtro com estrutura fibrilar. Embora o tamanho dos poros dos filtros fosse igual - as diferenças estruturais mostradas pelo MEV eram semelhantes -, não seria justo atribuir as alterações de eficiência apenas às diferenças estruturais. O uso ao mesmo tempo de provas microbiológicas e físicas para avaliar a eficácia foi outro aspecto importante deste experimento.


Subject(s)
Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Cognition Disorders/therapy , Depressive Disorder, Major/therapy , Executive Function/physiology , Psychotherapy/methods , Comorbidity , Cognition Disorders/diagnosis , Cognition Disorders/epidemiology , Depressive Disorder, Major/epidemiology , Severity of Illness Index , Treatment Outcome
5.
Arq. bras. med. vet. zootec ; 66(3): 688-696, 06/2014. tab, graf
Article in English | LILACS | ID: lil-718079

ABSTRACT

In autumn 2011 in cyprinid farms located in Iasi on the Jijia river, several infections with bacterial strains and macroscopical external cysts on the skin were diagnosedwhich developed as a result of the stress induced by biotic and abiotic factors. On the examination of the cyst contents the presence of numerous spores was observed, mostly of the Dermocystidium sp genusThe samples were taken from the common carp (Cyprinus carpio) and crucian carp (Carassius auratus gibelio) species from the fish farm as well as from the Jijia River. 35 fish were examined, all of them showing cysts, fragmentation of their dorsal fin and congestion of the gills. Histological examination of the skin showed a field of multiple dermal cysts with round light eosinophilic formations (14-16µm) containing a central refractable body similar to that reported for Dermocystidium sp. Gills samples were taken from the affected areas for the SEM examination with the purpose of evaluating not only aspects of normal morphology, but also aspects of some modifications of the affected areas as well as the presence of the etiologically incriminated bacteria Pseudomonas fluorescens. The isolates were identified through phenotypic methods. All the strains that showed mobility and oxidase-positivity were tested using API 20 NE strip. Consequently, they were taxonomically grouped into the species Pseudomonas fluorescens. The scanning electron microscope (SEM) was used for the first time in the characterization of the bacterial lesions produced by Pseudomonas strains on Cyprinus carpio and Carassius auratus gibelio gills. The diagnosis of septicemia with conditional pathogen species of Pseudomonas fluorescens was correlated with the results of the physico-chemical investigations of water and the data concerning the breeding conditions of the investigated livestock...


No outono de 2011, em fazendas de ciprinídeos localizadas em Iasi, no rio Jijia, diversas infecções bacterianas e cistos externos macroscópicos na pele se desenvolveram como resultado do estresse induzido por fatores bióticos e abióticos. No exame do conteúdo dos cistos, a presença de diversos esporos foi observada, a maioria do gênero Dermocystidium sp. As amostras foram colhidas das seguintes espécies: carpa comum (Cyprinus carpio) e carpa cruciana (Carassius auratus gibelio) de fazenda piscícola, além do rio Jijia. Assim sendo, 35 peixes foram examinados, todos demonstrando cistos, fragmentação da barbatana dorsal e congestão das guelras. O exame histológico da pele mostrou um campo de múltiplos cistos dérmicos com formações circulares claras eosinofílicas (14-16µm) contendo corpo central refratado similar ao relatado para Dermocystidium sp. Amostras de guelras foram retiradas das áreas afetadas para exame MEV, com o propósito de se avaliar não apenas os aspectos da morfologia normal, mas também os aspectos de algumas modificações das áreas afetadas, além da presença da bactéria etiologicamente incriminada: Pseudomonas fluorescens. Os isolados foram identificados por meio de métodos fenotípicos. Todas as amostras que mostraram mobilidade e positividade-oxidase foram testadas usando-se fita API 20 NE. Consequentemente, estas foram taxonomicamente agrupadas na espécie Pseudomonas fluorescens. O microscópio eletrônico de varredura (MEV) foi usado pela primeira vez na caracterização de lesões bacterianas produzidas por Pseudomonas nas guelras de Cyprinus carpio e Carassius auratus gibelio. O diagnóstico de septicemia com espécies condicionais de patogênico de Pseudomonas fluorescens foi correlacionado com os resultados das investigações físico-químicas da água e de dados sobre as condições de reprodução dos animais investigados...


Subject(s)
Animals , Carps/microbiology , Carps/parasitology , Dermcidins , Bacterial Infections/veterinary , Parasitic Diseases, Animal , Pseudomonas fluorescens/isolation & purification , Abiotic Factors , Biotic Factors
6.
Rev. bras. odontol ; 69(2): 242-245, Jul.-Dez. 2012. ilus, graf, tab
Article in Portuguese | LILACS | ID: lil-720350

ABSTRACT

O objetivo deste trabalho foi analisar a influência do tipo de cimento e do modo de ativação na espessura da linha de cimento de copings metálicos cimentados sobre pilares protéticos. Foram utilizados 6 pilares e 6 cilindros do sistema Cera One cimentados com cimento autoadesivo RelyX U200 (3M ESPE, St. Paul - EUA) e também um cimento de fosfato de zinco (S.S. White Artigos Dentários Ltda. - Rio de Janeiro - RJ - Brasil). Foram cimentados 2 cilindros com fosfato de zinco, 2 cilindros com RelyX fotoativado e 2 não fotoativados sendo levados ao microscópio eletrônico de varredura para mensuração da linha de cimento. A diferença entre os grupos foi pequena e o modo de ativação do cimento autoadesivo interfere pouco na espessura da linha de cimento de copings metálicos cimentados sobre pilares protéticos.


The aim of this study was to analyse the effect of the luting agent and the cure mode on the marginal opening of metal copings luted to implant abutments. To test a self-adhesive resin cement and a zinc phosphate cement, were used 6 abutments and 6 cylinders of the Cera One system. The cylinders were luted 2 with zinc phosphate cement, 2 with resin cement light cured and 2 with resin cement not light cured. Afterwards the cylinders were taken to SEM analysis to calculate the marginal opening. The cure mode has a little effect on the marginal opening of metal copings luted to implant abutments.


Subject(s)
Microscopy, Electron, Scanning , Cementation , Resin Cements
7.
São José dos Campos; s.n; 2011. 155 p. ilus, tab, graf.
Thesis in Portuguese | LILACS, BBO | ID: lil-642726

ABSTRACT

Este estudo avaliou o efeito do peróxido de hidrogênio a 38% e de diferentes agentes antioxidantes sobre a rugosidade superficial, a morfologia e a força de adesão do esmalte e da dentina. Trinta e seis terceiros molares recém extraídos foram selecionados e distribuídos aleatoriamente em 12 grupos (n=6) de acordo com: 1) substrato (esmalte ou dentina), 2) clareamento com peróxido de hidrogênio a 38%, 3) aplicação dos agentes antioxidantes (ascorbato de sódio, catalase e peroxidase), 4) momento (24 horas e envelhecimento atificial). Os grupos foram clareados com peróxido de hidrogênio a 38% (Opalescence Boost) e restaurados com Single Bond Plus+Filtek Z250. Os espécimes foram testados após 24 horas e após o envelhecimento artificial (20000 ciclos térmicos e 1200000 ciclos mastigatórios). Os dados foram submetidos ao Teste de Kruskal-Wallis e à comparações múltiplas a 5% de significância. Além disso, nove incisivos centrais e 32 terceiros molares foram selecionados e avaliados pelo Microscópio de força atômica e Microscópio eletrônico de varredura por Emissão de Campo. A rugosidade média do esmalte e da dentina (n=9) e a sua morfologia (n=3) foram avaliadas em três diferentes períodos: 1) antes do clareamento, 2) depois do clareamento e 3) depois da aplicação dos agentes antioxidantes. A análise de variância de 1 fator e o Teste de Tukey foram realizados a 5 % de significância para avaliar a rugosidade. A peroxidase aumentou a rugosidade superficial do esmalte (P<,0001). O peróxido de hidrogênio a 38% e todos os agentes antioxidantes aumentaram a rugosidade da dentina (P<,0001). Uma leve descalcificação superficial do esmalte foi observada após o clareamento. A smear layer não foi removida independente do tratamento usado. A força de adesão ao esmalte e à dentina foi reduzida após o clareamento e após a aplicação dos agentes antioxidantes. Os agentes antioxidantes não foram capazes de reverter a força de adesão ao esmalte e à dentina clareados...


The aim of this study was to assess the effect of 38% hydrogen peroxide and different antioxidant agents on surface roughness, ultra-structural morphology, and microtensile bond strengths to enamel and dentin. Thirty-six freshly extracted third molars were selected and randomly assigned into 12 groups (n=6) according to: 1) substrate (enamel or dentin), 2) bleaching with 38% hydrogen peroxide, 3) application of antioxidant agents (sodium ascorbate, catalase and peroxidase), and 4) moment (24 hours and artificially aged). Groups were bleached with 38% hydrogen peroxide (Opalescence Boost) and restored with Single Bond Plus+Filtek Z250. The specimens were tested after 24 hours and after long-term artificial aging (20,000 thermal cycles and 1,200,000 mechanical loading cycles). The data were submitted to Kruskal-Wallis analysis followed by multiple comparisons (P<.05). Additionally, nine central incisors and thirty-two third molars were selected and processed for Atomic Force Microscopy and Field Emission Scanning Electron Microscopy. The mean enamel and dentin roughness (n=9) and ultra-structural morphology (n=3) were evaluated in different periods: 1) before the bleaching, 2) after the bleaching, and 3) after the application of the antioxidant agents. A 1-way ANOVA/Tukey post-hoc test (P<.05) was computed for roughness. Peroxidase increased significantly enamel roughness (P<.0001). The 38% hydrogen peroxide and all antioxidant agents increased significantly dentin roughness (P<.0001). A mild etching pattern was observed on enamel after bleaching. Smear layer was not removed irrespective of the treatment used. The microtensile bond strengths to enamel and dentin were reduced after bleaching and after application of antioxidant agents. Antioxidant agents were not effective in reversing bond strengths of bleached enamel and dentin. Bleached enamel and dentin can be effectively restored 7 days post-bleaching...


Subject(s)
Humans , Dental Enamel , Dentin , Hydrogen Peroxide , Microscopy, Atomic Force , Microscopy, Electron, Scanning , Tensile Strength
8.
Odontol. clín.-cient ; 9(2): 151-154, abr.-jun. 2010. ilus
Article in Portuguese | LILACS, BBO | ID: biblio-874155

ABSTRACT

O objetivo deste estudo é avaliar qualitativamente a rugosidade superficial de uma porcelana submetida à três diferentes sistemas de polimento. Dessa maneira, foram confeccionados 48 corpos de prova de porcelana VITAVM®9 (VITA Zahnfabrik), sendo desgastadas com pontas diamantadas e divididos em três grupos: Grupo 1- polimento com borrachas abrasivas (Edenta), feltro e pasta diamantada; Grupo 2- polimento com borrachas (Sistema Shofu), feltro e pasta diamantada e Grupo 3- disco de óxido de alumínio (Sof-Lex), feltro e pasta diamantada. Posteriormente, os corpos de prova foram fotografados ao Microscópio Eletrônico de Varredura (MEV), com ampliações de 1.000 vezes, sendo em seguida suas rugosidades superficiais analisadas. Comparando as superfícies entre si, observou-se diferenças na quantidade e qualidade das ranhuras de cada corpo de prova. Dentro das limitações desse estudo, conclui-se que o Shofu foi o melhor sistema de polimento utilizado.


The aim of this study is to evaluate qualitatively the surface roughness of a porcelain subjected to there different polishing systems. Forty-eight samples were manufactured of percelain VITAVM®9 (VITA Zahnfabrik), whose surfaces were worn away with diamond burs and divided into three groups: Group 1 was polished with rubber abrasive (Edentulous), felt and folder diamond; Group 2 was polished with rubber abrasive (Shofu), felt and diamond paste; and Group 3 was polished with disk of aluminum oxide (Sof-Lex), felt and folder diamond. Later, the samples were photographed by the scanning electron microscope (SEM), with extensions of 1.000 times and then each surface roughness were analized. It was made a comparison between the areas of the samples and was observed the difference in the quantity and quality of the slots of each one. With the limitations of the study, the Shofu system of polishing was considered the best among the other kind of tested systems.


Subject(s)
Dental Materials , Dental Polishing , Dental Porcelain
9.
RSBO (Impr.) ; 6(2): 129-134, jun. 2009. ilus, tab
Article in Portuguese | LILACS-Express | LILACS | ID: lil-514880

ABSTRACT

Introdução: As cerâmicas são consideradas uma excelente alternativa como material estético restaurador, entretanto questões relevantes, como adaptação marginal, exigem um maior critério na confecção quando comparadas aos sistemas convencionais. Objetivo: Este trabalho avaliou a adaptação marginal de uma coroa In-Ceram confeccionada sobre um dente que, após 3 anos, teve sua extração indicada pela ortodontia. Material e métodos: A avaliação deu-se por meio de microscópio eletrônico de varredura. Resultados e conclusão: Foram encontrados valores de falta de adaptação entre 157 e 390 um, obtendo uma média estatística acima do considerado aceitável clinicamente pela literatura.


Introduction: Ceramics are considered an excellent choice as esthetic restorative material, but relevant questions like marginal fit require more attention in manufacturing than conventional systems. Objective: This work evaluated the marginal adaptation of an In-Ceram crown over a tooth that, after three years, had been indicated to extraction by orthodontics. Material and methods: The evaluation was by mean scanning electron microscope. Results and conclusion: It was found values of gaps between 157 and 390 um, getting a statistic average considered greater than the accepted by literature.

10.
Araraquara; s.n; 2000. 121 p. ilus, tab.
Thesis in Portuguese | BBO, LILACS | ID: biblio-864048

ABSTRACT

O objetivo deste estudo é avaliar ao Microscópio Eletrônico de Varredura (MEV) e Rugosímetro o efeito da afiação com e sem lubrificante utilizando três tipos de pedras de afiar sobre o ângulo de corte das curetas e o efeito sobre a superfície radicular instrumentada. Para isso foram selecionadas 24 curetas novas marca Neumar e distribuídas aleatoriamente em 8 grupos experimentais: curetas novas, curtas sem corte, curetas afiadas com pedras de Arkansas, Óxido de Alumínio e Carborundum com e sem lubrificante. Posteriormente as lâminas das curetas foram separadas das hastes e fotografadas ao MEV onde obtiveram-se fotomicrografias que foram avaliadas por 3 examinadores diferentes designando-se valores para cada foto de acordo ao Índice Modificado do Ângulo de Corte, da melhor a pior condição encontrada. Na segunda parte da pesquisa repetiu-se todos os passos da primeira fase, com a diferença que as lâminas não foram separadas das hastes, efetuando-se a instrumentação radicular sobre dentes provenientes de um bando de dentes pré-existentes de acordo com cada grupo experimental, procedimento realizado com um aparelho padronizador desenhado especificamente para este estudo. Posteriormente as áreas instumentadas foram separadas para análise ao Rugosimetro e logo tomadas fotomicrografadas ao MEV que foram avaliadas por 3 examinadores diferentes designando-se valores para cada foto de acordo ao Índice Modificado de Irregularidade Superficial, da melhor a pior condição encontrada. Os resultados obtidos foram enviados para análise estatística. Conforme os resultados, conclui-se: o lubrificante não exerceu influência significante sobre o ângulo de corte e a superfície radicular, sendo que o fator tipo de pedra exerceu um efeito direto sobre o ângulo de corte e a superfície radicular. As pedras de Arkansas com e sem lubrificante tiveram os melhores resultados, as pedras de Óxido de Alumínio os piores e as pedras de Carborundum com e sem lubrificante uma posição intermediária entre as duas anteriores, em termos de lisura do ângulo de corte e superfície radicular. Precisa-se de estudos adicionais para estabelecer o efeito lubrificante em termos de lisura do ângulo de corte e a superfície radicular


The purpose of this work was the assessment on Scanning Electron Microscope (SEM) and Perfilometer the effect of sharpen with three kinds of sharpen stones using or not lubricant over curet's cutting edges and the effect over instrumentated root surface. Twenty-four Neumar curets were selected and ramdomly distributes in eight experimental groups: new curets, dull curets, resharpened curtes with Arkansas stone, Aluminium Oxide and Carborundum with and without lubricant. Subsequently, the curet blades were separated from the handle and photographed on SEM. The photographs were examinated by three diferent examiners and the values given, according to the index of cutting edge, from better to worse were found. In the second part of the work, all the steps of the first phase were repeated except that the blades were not separated from the handle. The instrumentation of the experimental groups were done with the patterned apparatus on root segments from a teeth bank source. The instrumented areas were separated and a Perfilometer analysis and SEM photographs were made and analysed by the examiners. It was conclude from the statistical analysis that the lubricant did not highly influence the cutting edge and root surface. The type of stone influenced directly the cutting edge and root surface. The Arkansas's stone with and without lubricant show the highest result while the Aluminium Oxide stone the lowest. The carborundum stones with and without lubricant show intermediated results. Further studies are necessary to stablish the lubricant effecting on cutting edge smoothness and root surface


Subject(s)
Statistics, Nonparametric , Dental Instruments , Lubrication , Microscopy, Electron, Scanning , Dental Scaling
SELECTION OF CITATIONS
SEARCH DETAIL